GENERAL INFORMATION
AutoMic-i600 is automated system for rapid and accurate biochemical identification of microorganisms and antimicrobial susceptibility testing (AST) with determination of MIC (Minimum Inhibitory Concentrations).
KEY FEATURES
- Rapid bacterial identification based on biochemical testing and comparison with an extensive database
- The identification system uses a dynamic continuous-monitoring method, allowing identification times to be reduced to 3 - 20 hours
- Automated antimicrobial susceptibility testing (AST) with sample inoculation, incubation, and result reading based on the broth microdilution method, compliant with the latest EUCAST standards
- Precise and reliable quantitative determination of MIC through real-time monitoring of microbial growth, ensuring accurate and reproducible results
- Automatic correction of antimicrobial susceptibility interpretation for intrinsic and acquired resistance, including ESBL-producing organisms, CRE, MRSA, VRE, PRSP, high-level aminoglycoside resistance (HLAR), and inducible clindamycin resistance, in accordance with EUCAST expert interpretation rules
- Two detection methods - colorimetric and turbidimetric - for maximum accuracy
- Intelligent AI-based algorithm that enhances result reliability
- Capacity of up to 64 samples simultaneously, suitable for laboratories with varying workloads
- Fully automated workflow, including inoculation, incubation, and result reading
- Direct export to WHONET for easy reporting and data analysis
TECHNICAL SPECIFICATIONS
- Capacity: 64 samples
- Injection method: automated sample addition
- Pipetting speed: <3 minutes / 120 samples
- Pipetting accuracy: 50 μl ± 3 μl / 100 μl ± 3 μl / 150 μl ± 3 μl
- Pipetting repeatability: 50 μl, 100 μl, 150 μl, CV ≤ 3%
- Incubation zone temperature: 35℃ ± 1.5℃
- Monitoring frequency: every 30 minutes
- Wavelength range: 400 nm ~ 700 nm
- Light source: LED
- Number of filters: up to 6
AVAILABLE TEST CARDS:
Antibiotic Susceptibility Panels
1. Gram-positive - including 20 antibiotics
- Range of application - Staphylococcus, Enterococcus, Bacillus
2. Enterobacteriaceae - including 26 antibiotics
- Range of application - Enterobacteria
3. Non-fermenting - including 22 antibiotics
- Range of application - Pseudomonas, Acinetobacter, Burkholderia cepacian, Stenotrophomonas maltophilia
4. Streptococcus - including 19 antibiotics
- Range of application - Streptococcus
5. Fungus - including 10 antibiotics
- Range of application - Candida, Cryptococcus and Aspergillus
Combined identification and antimicrobial susceptibility testing cards
1.Gram-positive - including 19 antibiotics
- Range of application - Corynebacterium, Bacillus, Listeria, Staphylococcus, Streptococcus, Enterococcus, Micrococcu etc.
2. Gram-negative - including 20 antibiotics
- Range of application - Salmonella, Shigella, Escherichia, Pantoea, Morganella, Yersinia, Pseudomonas, Acinetobacter, Moraxella, Bordetella, Vibrio, Aeromonas, Pasteur bacteria, etc.
3. Yeast - including 9 antibiotics
- Range of application - Yeast type fungal
Identification cards
1. Gram-positive
- Range of application - Corynebacterium, Bacillus, Listeria, Staphylococcus, Streptococcus, Enterococcus, Micrococcu etc.
2. Gram-negative
- Range of application - Salmonella, Shigella, Escherichia, Pantoea, Morganella, Yersinia, Pseudomonas, Acinetobacter, Moraxella, Bordetella, Vibrio, Aeromonas, Pasteur bacteria, etc.
3. Neisseria and Haemophilus - Coming soon
- Range of application - Neisseria и Haemophilus
Detection of resistance phenotypes:
- MRSA: Methicillin-resistant Staphylococcus aureus
- D test: Erythromycin induces Clindamycin resistance
- VISA:Vancomycin-mediated Staphylococcus aureus
- VRSA: Vancomycin-resistant Staphylococcus aureus
- VRE: Vancomycin-resistant Enterococcus
- PRSP: Penicillin-resistant Streptococcus pneumoniae
- HLAR: High-level aminoglycoside-resistant Enterococci
- ESBL: Extended-spectrum β-lactamase producing bacteria
- CRE:Carbapenem-resistant Enterobacteriaceae